1 · Select your team
2 · Who is capturing?

Sample names. Device remembers the last team — next sign-in is one tap + PIN.

Jovitech
Today's sites
Fri 9 Oct · Team A — Johor South
E1
1Not started
2In progress
1Synced

New site

Step 1 of 2 · Site info
JHR-
Format OK · not used by any other site on this device
GPS captured
1.4655° N, 103.7578° E
±4 m accuracy · 10:31 · sample
Tower type Tap one
Rough value — measured geometry is captured in the next step.

Site checklist

JHR-0001 · 62% complete
62%
JHR-0001
Sample Site — Lattice
MaxisLattice 4-leg45 m
Sections 6 of 8 started
After TPM

TCM decision

JHR-0001 · Stage 2 of 4
TPMAnalysisFab listTCM
EXAMPLE DATA — for mockup only
Client & analysis tool
Client: MaxisMStower
Export file: JHR-0001_TPM.std (MStower)
Maxis › MStowerEP (Edgepoint) › Open Tower
Tool is set by client. EP sites export to Open Tower instead.
TPM data
✅
TPM submitted
Today 10:44 · 25 photos · 8 panels
✅
Exported to MStower
Sent 11:02 · JHR-0001_TPM.std
Sent
Analysis result MStower · 29 Oct
Member stress checkFAIL
Fail if utilisation > 0.90 · max 1.18 · 4 members fail
MemberLocationSectionUtil.
LegP2 · Leg AL100×101.18
FAIL
Diag. braceP3 · Face 1L50×51.09
FAIL
Diag. braceP3 · Face 2L50×51.04
FAIL
Horiz.P4 · Face 1L45×40.92
FAIL
Horiz.P4 · Face 2L45×40.84
PASS
Visual defects from TPM 5 found · Major / Minor
!
Rust Major
P1–P2 legs, base plates · pitting
!
Bent bracing Major
P3 · Face 1 · diagonal
!
Missing members Major
P5 · Face 3 · 1 horizontal
!
Loose / missing bolts Major
P2 leg splice · 6 loose, 2 missing
!
Damaged ladder & platform Minor
2 rungs bent · grating corroded
🎨
Paint peel-off (overall tower)
Painting needed if > 50%
35 %
Verdict by scope
TCM required: YES
2 of 3 scopes required
Maintenance
Major rust P1–P2, bent brace P3, missing horizontal P5, 2 missing / 6 loose bolts
Required
Strengthening
4 members fail (util. > 0.90, max 1.18): add / upgrade members
Required
Painting
Paint peel-off 35%, not more than 50% of tower
Not required
Engineer approvalApproved
Ir. A. Example (Structural) · 30 Oct 2026, 09:15

Fabrication & install

JHR-0001 · 10 items
TPMAnalysisFab listTCM
EXAMPLE DATA — for mockup only
Totals by scope
Totals by status
Bill of items Pending › In fab › Galvanising › QC › Ready / Delivered › Installed
Approvals
✅
Engineer approval: TCM verdict
Ir. A. Example · 30 Oct 09:15
🔒
Warehouse release approval
Needed before list goes to warehouse · Pending

TCM handoff

JHR-0001 · Stage 4 of 4
TPMAnalysisFab listTCM
EXAMPLE DATA — for mockup only
TCM work order WO-TCM-0001
10 items · Maintenance 6 · Strengthening 4 · Painting 0
Readiness
✅
Engineer approval
Ir. A. Example · 30 Oct
❌
Warehouse release approval
Pending · required before sending
🔒
List sent to warehouse
Locked until release approval
❌
Fabricated items galvanised, QC passed & delivered
1 of 6 delivered · ETA 6 Nov
❌
Climb crew & permit booked
Not yet scheduled
On-site scope
Maintenance: Required
• Treat rust P1–P2 (Major)
• Replace bent brace P3-F1, missing horizontal P5
• Replace / tighten bolts at P2 splice
• Replace 2 ladder rungs, platform grating
Strengthening: Required
• Upgrade leg P2-A, braces P3-F1/F2, horizontal P4-F1 (util. > 0.90)
Painting: Not required
• Peel-off 35% (limit: more than 50%)

Site photos

JHR-0001
✅Captured❌Missingn/aNot applicable
Google DriveNot connected

Geometry · Monopole

JHR-0002 · 35% complete
Elevation
Total height
Base Ø
Top Ø
Sections
Sections Tap a row to edit
SecElev.mBot ØmmTop Ømmtmm

Geometry · Lattice

JHR-0001 · 62% complete
Face elevation
Total height
Base face width
Top face width
Panels / levels Tap to edit
PanelElev.mFace W topmmBrace

Appurtenances

JHR-0001 · 8 items · 62%

Add appurtenance

120° TN
Sector A · B · C
Size (H × W)
Mounted on

New defect

JHR-0001 · Defect #4
Rust · bolts SAMPLE PHOTO (illustration)
1.4655°N 103.7578°E
09 Oct 10:42 · facing 118° · auto-tagged
2 photos · min 1
Category
Severity
Major: office is notified on next sync. Add a close-up photo.
Member location
TagFace A–B · P3 · Diagonal · 14.5 m
Face
Member
Elevation (auto-sets panel)
Note optional

Review & submit

JHR-0001 · 62% complete
TowerLattice 4-leg
Height · panels45.0 m · 8
Appurtenances8 items
Defects3 · 1 major
Photos16 / 25
Members14 / 35
Needs attention 3 blocking · 1 warning
FoundationPad / pile dimensions missing
Photos9 photos missing (cable size/qty, tower views, sketches…)
MembersLeg size not set for P6–P8
GeometryP5 face width differs from design by 6%
Sign-off
Engineer 1 (sample) · 09 Oct 2026
I confirm the data was measured on site and photos are unedited.
Will queue offline and upload on next sync.
Outputs
STAGE 1 OUTPUT · not in this build
Jovitech

JHR-0001 Sample Site — Tower geometry

Maxis · Lattice 4-leg · 45 m · 62% complete
Total height
Base face width
Top face width
PanelFrommTomFace W botmmFace W topmmBraceLeg anglemm
Face elevation · live